+

220V 1 Saluran Modul Waktu Tunda Pemicu LED Display Otomatis Digital Modul Sakelar Relai Kontrol Waktu Tunda

USD 4.80USD 7.39

220V 1 Saluran Modul Waktu Tunda Pemicu LED Display Otomatis Digital Modul Sakelar Relai Kontrol Waktu Tunda

Description
Product selling point: 1. Using high-quality materials, the quality is guaranteed 2. Industrial grade PCB board, stable performance and long service life 3. Adopt photoelectric isolation input and output to improve anti-interference ability and power consumption 4. Setting parameters can be memorized when power off 5. Wide application Parameter: 1. The signal triggers the relay to close, the time is up, the relay is disconnected, during the delay period A: Retriggering is invalid B: Trigger re-time again C: Trigger the relay reset again to terminate the timing 2. The signal trigger starts timing time T1, when the time is up, the relay pull-in time T2 is disconnected (reset) The time of T1 and T2 is adjustable 3. Cycle use: T1 is turned on, T2 is turned off, and the cycle is infinite. Both T1 and T2 time are adjustable 4. There is a signal, the relay pulls in, keeps pulling in, the signal disappears, the timing starts, the time is up, the relay is disconnected, during the delay period, the signal is given again, the delay is canceled, the signal disappears, and the timing is restarted The output is equivalent to a passive contact switch The relay pulls in, the normally open terminal and the common terminal are connected, and the normally closed terminal and the common terminal are disconnected; Working mode selection: After turning on the power, press and hold K for 12 seconds to enter the selection function mode, P1-1~P1-4 can be selected, P1-1 working mode: the signal triggers the relay to pick up, the time is up, the relay is disconnected. User can choose Set the time T for the relay to pull in, press K2 and the hundreds-digit digital tube starts to flash. At this time, press K3, and the hundreds-digit change; press K2 and the ten-digit digital tube starts to flash. At this time, press K3, and the ten-digit change ;Press K2 and the one-digit digital tube starts to flash, press K3 at this time, the one-digit number changes; press K2 again, the digital tube no longer flashes, press K3 at this time, the decimal point shifts, and the decimal point in the one-digit represents 0 To 999 minutes, the ten place represents 0 to 99.9 seconds without a decimal point, which means 0 to 999 seconds; after the selection is complete, the time setting is completed. Short press K1, you can enter the fine adjustment settings of the function, the trigger is invalid during the default delay, press K1 once, the trigger is valid during the delay (re-time), press K1, reset during the delay (time off, relay reset), Press again to repeat the default first setting. P1-2 working mode: The signal triggers to start timing X time, and the relay pulls in Y and disconnects. The user can set the time X, Y for the relay to pull in; the time setting is similar to P1-1, except that the blue light is on to indicate the time for the relay to be closed, and the blue light is off to indicate the time for the relay to be disconnected. Short press K1, you can enter the fine adjustment settings of the function, the trigger is invalid during the default delay period, press K1 once, the trigger is valid during the delay period (re-timing), and press again to repeat the default first setting. P1-3 working mode: ON for X seconds, OFF for Y seconds, infinite loop. The user can set the time X, Y for the relay to pull in; the time setting is similar to P1-2. Short press K1, you can enter the fine adjustment settings of the function, first turn on X, turn off Y seconds, press K1, first turn off X, turn on Y seconds, press again to repeat the default first setting. P1-4 working mode: the signal triggers the relay to pull in but does not start the timing, the trigger signal disappears and starts timing T, when the time is up, the relay is disconnected; during the delay period, the signal is given again, the delay is canceled, the pull-in is maintained, the signal disappears, Restart timing; (equivalent to start timing when the button is released, often used for power-off delay). The user can set the time T for the relay to pull in; the time setting is similar to P1-1. Package Included: 1* Timing module

Specification

Condition : New

Origin : Mainland China

is_customized : Yes

Package : SMD

Brand Name : diymore

Type : Voltage Regulator

Application : Computer

5 Buah PK618BA MOSFET QFN-8
USD 3.85USD 4.70
+